ND experiment
Physics
At the beginning of 80s the leading cross sections of the electron -positron annihilation in the final states with charged particles were measured in the energy range 2E=0.5-1.4 GeV. Processes with the neutral particles in the final state were less studied. To investigate the radiative decays of the ρ 0 , ω , and ϕ mesons and other processes involving photons , π 0 , and η mesons the ND
was constructed. Its distinguishing features are defined by the specially designed electromagnetic calorimeter based on NaI (Tl) scintillation counters .
List of published analyses
e + e − → ρ , ω , ϕ → π 0 γ , η γ
ϕ → η ′ γ
Rare decays of the ρ 0 , ω , and ϕ mesons
ω , ϕ → π 0 e + e −
ϕ → π + π −
ρ → π + π − π 0
ω , ϕ → π 0 π 0 γ
ϕ → π 0 η γ
light scalars a 0 ( 980 ) and f 0 ( 975 ) in ϕ -meson radiative decays
e + e − → ω π 0
e + e − → π + π − π 0 , π + π − η
e + e − → π + π − π + π − , π + π − π 0 π 0
e + e − → γ γ γ γ
e + e − → e + e − γ γ
e + e − → e + e − e + e −
e + e − → e + e − γ (virtual Compton scattering )
Analyses of other processes
Measurement of the ω-meson parameters
Upper limits on electron width of scalar and tensor mesons f 0 ( 975 ) , f 2 ( 1270 ) , f 0 ( 1300 ) , a 0 ( 980 ) , and a 2 ( 1320 )
ϕ → π + π − π 0 , K S 0 K L 0
Search for
e + e − → π 0 π 0 γ
K S 0 → γ γ
e + e − → C ( 1480 ) → ϕ π 0
Detector
Neutral Detector r-φ view.
Neutral Detector r-θ view; 1-vacuum chamber of the storage ring, 2-cylindrical proportional chambers, 3-plastic scintillation counters, 4-NaI(Tl) counters, 5-flat proportional chambers, 6-iron absorber, 7-anticoincidence counters.
Based on goals of the physics program the ND consist of
Electromagnetic calorimeter
168 rectangular NaI (Tl) scintillation counters
total mass of NaI (Tl) is 2.6 t
solid angle coverage is 65% of 4π sr
minimum thickness is 32 cm or 12 radiation length
energy resolution for photons is σ/E = 4% / √ E
Charged particle coordinate system
3 layers of coaxial cylindrical 2-d wire proportional chambers in the center of the detector
solid angle coverage is 80% of 4π sr
angular resolution is 0.5° in the azimuthal and 1.5° in the polar direction
surrounded by the 5-mm thick plastic scintillation counter for trigger
Flat (shower) coordinate 2-d wire proportional chambers
2 layers of flat 2-d wire proportional chambers.
angular resolution is 2° in the azimuthal and 3.5° in the polar direction for 0.5 GeV photons
Iron absorber & anti-coincidence counters
The electromagnetic calorimeter is covered by the 10-cm thick iron absorber and plastic scintillation anti-coincidence counters.
Results
Data collected with the ND experiment corresponds to the integrated luminosity 19 pb−1 .
Results of the experiments with ND are presented in Ref.,
and are included in the PDG Review.